PRODUCTS
Wire & Cable, Cable Accessories, Telecom Accessories, Energy Saving Lamp(CFL)...
KT0712 RG6U + 2C/18AWG Siamese 95% BC CLASS 5 Siamese CMR
 
View Larger
KT0712 RG6U + 2C/18AWG Siamese 95% BC CLASS 5 Siamese CMR
 
KT0712 RG6U 95% BC + 2C-18AWG BC CLASS 5 Siamese CMR
Construction Parameters:
  Inner Conductor 0.04"/1.02mm/18AWG Copper 
  Dielectric 0.175" /4.45mm  Foamed PE           
  Shield 1 Bonded Aluminum Foil Shield
  Shield 2 Bare Copper braid wire 95% coverage  
Nominal Diameter Over Shielding: 0.20"/5.1 mm
  Jacket 0.262±0.006"/6.65±0.15mm  PVC (NEC RISER)
Flame Retardation: The cable shall meet IEC 60332-1
  Power Wire Conductor 2 - 18 AWG 16×0.001"/16×0.254mm Bare Copper
  Power wire Diameter of insulation 0.075"/1.90mm PVC (NEC RISER)
  Power Wire Color Code Red,Black
  Jacket 0.199"/5.05±0.1mm PVC (NEC RISER)
  Application For Use in Longer CCTV Run Lengths
  Limited Length Typical run length up to 1600 feet
     
Electrical Characteristics:
  Inner Conductor Resistance The Max. at 20 shall be < 21.2 Ω/km (6.96 Ω/kft)
  Capacitance 52 ±3 pF/m                      17±0.3 pF/ft 
  Impedance 75 ± 3 Ω
  Return loss  between 5 and 1000MHz: > 22dB
  Velocity of Propagation  0.85
  Sparker Test (VAC) 4
     
Attenuation(20℃):
Frequency 
                      (MHZ)                     
Max Attenuation 
(dB/100ft)
Max Attenuation 
(dB/100m)
5 0.62  1.90 
55 1.72  5.25 
187 3.07  9.35 
211 3.28  10.00 
400 4.46  13.61 
500 5.01  15.29 
750 6.08  18.54 
860 6.56  20.01 
1000 7.05  21.49 