PRODUCTS
Wire & Cable, Cable Accessories, Telecom Accessories, Energy Saving Lamp(CFL)...
KT0305 1-2 RF
1-2" RF |
Construction Parameters: |
Inner Conductor |
0.189''/4.80mm Bare Copper/Copper Clad Aluminum
Wire |
Dielectric |
0.484''/12.30mm Foamed PE |
Outer Conductor |
Nom.0.543''/13.8mm Corrugated Copper Tube |
Jacket |
0.618''/15.7mm Black PE/Low Smoke Halogen-free Fire-retardant PE |
|
|
|
Electrical Characteristics: |
Capacitance |
76 pF/m 23.17pF/ft |
Impedance |
50 Ω |
Velocity of Propagation |
0.88 |
Peak Power Rating |
40 KW |
RF Peak Voltage |
1.6 KV |
Insulation Resistance |
>5000 M.Ω.KM |
Cut-off Frequency |
8.8 GHz |
Insulation Voltage |
6 KV |
Jacket Sparkt |
8 KV |
Shielding Effectiveness |
>120 dB |
|
|
|
Mechanical and Environmental: |
Min.Single Bending Radius |
1.97''/50 mm |
Min.Repeated Bending Radius |
4.925''/125 mm |
No. of Bends |
15 |
Tensile Strength |
350 kg |
Operating Temp. |
-55 to +85 ℃ |
|
|
|
Attenuation(20℃): |
Frequency
(MHZ) |
Attenuation
(dB/100m) |
Average Power
(KW) |
100 |
2.15 |
3.94 |
200 |
3.08 |
2.75 |
450 |
4.70 |
1.80 |
800 |
6.35 |
1.33 |
900 |
7.20 |
1.25 |
1000 |
9.05 |
1.18 |
1500 |
9.90 |
0.95 |
1800 |
10.50 |
0.86 |
2000 |
11.10 |
0.81 |
3000 |
13.20 |
0.65 |
|
|
|